Zum Hauptinhalt springen

Transplant Outcomes After Exposure of Deceased Kidney Donors to Contrast Medium.

Chotkan, KA ; Hilbrands, LB ; et al.
In: Transplantation, Jg. 108 (2024), Heft 1, S. 252-260
academicJournal

Titel:
Transplant Outcomes After Exposure of Deceased Kidney Donors to Contrast Medium.
Autor/in / Beteiligte Person: Chotkan, KA ; Hilbrands, LB ; Putter, H ; Konjin, C ; Schaefer, B ; Beenen, LFM ; Pol, RA ; Braat, AE
Zeitschrift: Transplantation, Jg. 108 (2024), Heft 1, S. 252-260
Veröffentlichung: Hagerstown, MD : Lippincott Williams & Wilkins ; <i>Original Publication</i>: Baltimore, Williams & Wilkins., 2024
Medientyp: academicJournal
ISSN: 1534-6080 (electronic)
DOI: 10.1097/TP.0000000000004745
Schlagwort:
  • Humans
  • Retrospective Studies
  • Graft Survival
  • Tissue Donors
  • Brain Death
  • Delayed Graft Function etiology
  • Kidney Transplantation adverse effects
  • Tissue and Organ Procurement
Sonstiges:
  • Nachgewiesen in: MEDLINE
  • Sprachen: English
  • Publication Type: Journal Article
  • Language: English
  • [Transplantation] 2024 Jan 01; Vol. 108 (1), pp. 252-260. <i>Date of Electronic Publication: </i>2023 Sep 06.
  • MeSH Terms: Kidney Transplantation* / adverse effects ; Tissue and Organ Procurement* ; Humans ; Retrospective Studies ; Graft Survival ; Tissue Donors ; Brain Death ; Delayed Graft Function / etiology
  • References: Berthier E, Ridereau-Zins C, Dubé L, et al. Simultaneous CT angiography and whole-body CT is an effective imaging approach before multiorgan retrieval. Diagn Interv Imaging. 2017;98:235–243. ; Gauthier JM, Bierhals AJ, Liu J, et al. Chest computed tomography imaging improves potential lung donor assessment. J Thorac Cardiovasc Surg. 2019;157:1711–1718.e1. ; Mensink JW, Pol RA, Nijboer WN, et al. Whole body CT imaging in deceased donor screening for malignancies. Transplant Direct. 2019;5:e509. ; Bozovic G, Adlercreutz C, Höglund P, et al. Imaging of the lungs in organ donors and its clinical relevance: a retrospective analysis. J Thorac Imaging. 2017;32:107–114. ; Tache A, Badet N, Azizi A, et al. Multiphase whole-body CT angiography before multiorgan retrieval in clinically brain dead patients: role and influence on clinical practice. Diagn Interv Imaging. 2016;97:657–665. ; Reyes J, Perkins J, Kling C, et al. Size mismatch in deceased donor liver transplantation and its impact on graft survival. Clin Transplant. 2019;33:e13662. ; Lormans P, Monbaliu D, Ferdinande P. Balancing cost and efficiency in screening potential organ donors with whole body CT. Transplant Direct. 2020;6:e621. ; Eurotransplant. Chapter 9: The donor. Eurotransplant Manual. Available at https://www.eurotransplant.org/wp-content/uploads/2022/11/H9-The-Donor-08-11-2022.pdf . Accessed June 12, 2022. ; Chotkan KA, Mensink JW, Pol RA, et al. Radiological screening methods in deceased organ donation: an overview of guidelines worldwide. Transpl Int. 2022;35:10289. ; MJM Pruppers IdW-S, H Bijwaard. Analyse van trends in stralingsbelasting als gevolg van beeldvormende diagnostiek. RIVM rapport 610003001/2013; 2013. Available at https://www.rivm.nl/bibliotheek/rapporten/610003001.pdf . Accessed June 12, 2022. ; OECD. Computed tomography (CT) exams, total 2013/1. 2013. Available at https://www.oecd-ilibrary.org/social-issues-migration-health/computed-tomography-ct-exams-total-2013-1_ct-exams-tot-table-2013-1-en . Accessed June 12, 2022. ; Tumlin J, Stacul F, Adam A, et al. Pathophysiology of contrast-induced nephropathy. Am J Cardiol. 2006;98(6, Supplement 1):14–20. ; van der Molen AJ, Reimer P, Dekkers IA, et al. Post-contrast acute kidney injury—part 1: definition, clinical features, incidence, role of contrast medium and risk factors: recommendations for updated ESUR Contrast Medium Safety Committee guidelines. Eur Radiol. 2018;28:2845–2855. ; Persson PB, Hansell P, Liss P. Pathophysiology of contrast medium–induced nephropathy. Kidney Int. 2005;68:14–22. ; Fähling M, Seeliger E, Patzak A, et al. Understanding and preventing contrast-induced acute kidney injury. Nat Rev Nephrol. 2017;13:169–180. ; Aycock RD, Westafer LM, Boxen JL, et al. Acute kidney injury after computed tomography: a meta-analysis. Ann Emerg Med. 2018;71:44–53.e4. ; McDonald JS, Leake CB, McDonald RJ, et al. Acute kidney injury after intravenous versus intra-arterial contrast material administration in a paired cohort. Invest Radiol. 2016;51:804–809. ; Schönenberger E, Martus P, Bosserdt M, et al. Kidney injury after intravenous versus intra-arterial contrast agent in patients suspected of having coronary artery disease: a randomized trial. Radiology. 2019;292:664–672. ; Mangus RS, Bajpai S, Lutz AJ, et al. Contrast administration to the deceased kidney donor has no impact on post-transplant outcomes. J Surg Res. 2020;254:261–267. ; Lesouhaitier M, Legeai C, Savoye E, et al. Impact of donor coronary angiography on kidney transplantation outcomes. Clin Transplant. 2018;32:e13355. ; Vigneau C, Fulgencio JP, Godier A, et al. The use of contrast media in deceased kidney donors does not affect initial graft function or graft survival. Kidney Int. 2006;70:1149–1154. ; Grosse K, Brauer B, Kücük O, et al. Does contrast medium administration in organ donors affect early kidney graft function? Transplant Proc. 2006;38:668–669. ; Dutch Transplantation Foundation. Annual Report Eurotransplant. Available at https://www.eurotransplant.org/wp-content/uploads/2022/06/Annual-Report-2021_HR.pdf . Accessed June 13, 2022. ; Annual report Dutch Transplantation Foundation . Available at https://www.transplantatiestichting.nl/files/Jaarverslag/nts-cijferbijlage-jaarverslag-2021.pdf?031832443f . Accessed June 13, 2022. ; Peters-Sengers H, Houtzager JHE, Idu MM, et al. Impact of cold ischemia time on outcomes of deceased donor kidney transplantation: an analysis of a national registry. Transplant Direct. 2019;5:e448. ; de Kok MJC, Schaapherder AFM, Alwayn IPJ, et al. Improving outcomes for donation after circulatory death kidney transplantation: science of the times. PLoS One. 2020;15:e0236662. ; Dutch Transplantation Foundation. Modelprotocol deceased organ- and tissue donation [In Dutch: Modelprotocol Postmortale orgaan- en weefseldonatie]. 2022. Availabe at https://www.transplantatiestichting.nl/files/Protocollen%20en%20richtlijnen/modelprotocol-versie-7-januari-2023-dd-26-04.pdf . Accessed June 13, 2022. ; Dutch Advisory Committee on Kidney Transplantation. Protocol Machineperfusion kidneys [In Dutch: Protocol Machinepreservatie van Nieren]. 2016. ; Levey AS, Coresh J, Greene T, et al.; Chronic Kidney Disease Epidemiology Collaboration. Using standardized serum creatinine values in the modification of diet in renal disease study equation for estimating glomerular filtration rate. Ann Intern Med. 2006;145:247–254. ; Peters-Sengers H, Heemskerk MBA, Geskus RB, et al. Validation of the prognostic kidney donor risk index scoring system of deceased donors for renal transplantation in the Netherlands. Transplantation. 2018;102:162–170. ; Rao PS, Schaubel DE, Guidinger MK, et al. A comprehensive risk quantification score for deceased donor kidneys: the kidney donor risk index. Transplantation. 2009;88:231–236. ; Dutch Society of Radiology. Initial radiodiagnostics for traumapatients (Dutch guidelines). 2019. Available at https://richtlijnendatabase.nl/richtlijn/initi_le_radiodiagnostiek_bij_traumapati_nten/startpagina_-_initiele_radiodiagnostiek_bij_trauma_patienten.html . Accessed June 21, 2022. ; Dutch Network of Acute Care. Landelijke traumaregistratie (Dutch trauma registration) 2015-2019. 2019. Available at https://www.lnaz.nl/cms/files/rapportage_landelijk_2020_-_v2.pdf . Accessed June 21, 2022. ; Moers C, Smits JM, Maathuis MH, et al. Machine perfusion or cold storage in deceased-donor kidney transplantation. N Engl J Med. 2009;360:7–19. ; GDPRhub. Article 9, General Data Protection Regulation. 2018. Available at https://gdprhub.eu/Article_9_GDPR#Racial_or_ethnic_origin . Accessed April 9, 2023.
  • Entry Date(s): Date Created: 20230920 Date Completed: 20231216 Latest Revision: 20231216
  • Update Code: 20231217
  • PubMed Central ID: PMC10718213

Klicken Sie ein Format an und speichern Sie dann die Daten oder geben Sie eine Empfänger-Adresse ein und lassen Sie sich per Email zusenden.

oder
oder

Wählen Sie das für Sie passende Zitationsformat und kopieren Sie es dann in die Zwischenablage, lassen es sich per Mail zusenden oder speichern es als PDF-Datei.

oder
oder

Bitte prüfen Sie, ob die Zitation formal korrekt ist, bevor Sie sie in einer Arbeit verwenden. Benutzen Sie gegebenenfalls den "Exportieren"-Dialog, wenn Sie ein Literaturverwaltungsprogramm verwenden und die Zitat-Angaben selbst formatieren wollen.

xs 0 - 576
sm 576 - 768
md 768 - 992
lg 992 - 1200
xl 1200 - 1366
xxl 1366 -