What can intracoronary pressure measurements tell us about CFR? Now comes pb-CFR
In: Catheterization and Cardiovascular Interventions, Jg. 90 (2017-11-15), S. 926-927
Online
unknown
Zugriff:
Key Points Pressure-bound (pb) coronary flow reserve (CFR) is a novel estimation of CFR, calculated from easily obtained baseline and hyperemic pressure assessment Validation of pb-CFR in previously reported lesions showed accuracy of 84% to CFR with sensitivity of 96% and specificity of 60% FFR >0.75 and low pb-CFR in DEFER was associated with increased angina and complications compared to high pb-CFR and this risk was not modified by elective revascularization.