Hemodialysis with Kiil-type artificial kidney--clinical study on disequilibrium syndrome
In: 泌尿器科紀要, Jg. 17 (1971-02-01), Heft 2, S. 89-99
Online
unknown
Zugriff:
350 times of hemodialysis were performed at Department of Urology, Hiroshima University Hospital during two years period, April 1967 to March 1969, with a modified Kiil dialyzer. Dialysis methods consisted of two-layer dialysis, two-layer dialysis with infusion of hypertonic solution, and one-layer dialysis. Clinical disequilibrium syndrome observed under the above methods was studied in conjunction with pre-and postdialysis BUN, serum osmolar changes, amount of water extraction and changes in acid-base balance.
Titel: |
Hemodialysis with Kiil-type artificial kidney--clinical study on disequilibrium syndrome
|
---|---|
Autor/in / Beteiligte Person: | Fukushige, Mitsuru ; Tado, Osamu ; Matsuki, Satoru ; Mizoguchi, Masaru ; Tanaka, Hiromi ; Nihira, Hiromi |
Link: | |
Zeitschrift: | 泌尿器科紀要, Jg. 17 (1971-02-01), Heft 2, S. 89-99 |
Veröffentlichung: | 京都大学医学部泌尿器科学教室, 1971 |
Medientyp: | unknown |
ISSN: | 0018-1994 (print) |
Schlagwort: |
|
Sonstiges: |
|