P-615 Lack of analytical interference of dydrogesterone in progesterone immuno-assays: a multi-laboratory spike and recovery study of widespread used assays
In: Human Reproduction ; volume 37, issue Supplement_1 ; ISSN 0268-1161 1460-2350, 2022
Online
academicJournal
Zugriff:
Study question Does dydrogesterone (DYD) and its active metabolite 20-α-dihydrodydrogesterone (DHD) interfere with routinely used progesterone assays? Summary answer This multi-laboratory spike-and-recovery study does not indicate any relevant interference of DYD/DHD within routinely used progesterone assays. What is known already Progesterone (P4), a sex steroid, is measured in serum or plasma by competitive immunoassay or Liquid Chromatography mass spectrometry (LC-MS) in a variety of clinical contexts. One potential limitation of steroid hormone immunoassays is interference caused by compounds with structural similarity to the target steroid of the assay. Dydrogesterone, an orally active close stereoisomer of progesterone, is used for various indications in women’s health, including luteal phase support. To date, the potential interference of DYD/DHD with P4 immunoassays has not systematically been studied. Study design, size, duration The present systematic in-vitro study investigated potential interferences of DYD/DHD in seven widely used, commercially available P4 immunoassays and a LC-MS method over a range of concentrations of DYD/DHD and P4. The study was performed in collaboration with participants in the endocrine section of the Dutch foundation for quality assessments in medical laboratories. For each assay method, each laboratory received a set of nine blinded human plasma samples (containing different P4 and/or DYD/DHD concentrations). Participants/materials, setting, methods Routine human plasma samples were anonymized and pooled to create three graded concentration levels of progesterone (P4 high, P4 medium, P4 low). Each pooled P4 plasma sample (6-7 ml) was spiked at high, medium and “none” DYD/DHD concentration and was divided into 0.5 ml aliquots. The blinded aliquots were analyzed by seven different laboratories with their routine progesterone assay (six different immunoassays and LC-MS assay, respectively). Main results and the role of chance High, medium, and low P4 samples had ...
Titel: |
P-615 Lack of analytical interference of dydrogesterone in progesterone immuno-assays: a multi-laboratory spike and recovery study of widespread used assays
|
---|---|
Autor/in / Beteiligte Person: | Eggersmann, T ; Wolthuis, A ; Van Amsterdam, P ; Griesinger, G |
Link: | |
Zeitschrift: | Human Reproduction ; volume 37, issue Supplement_1 ; ISSN 0268-1161 1460-2350, 2022 |
Veröffentlichung: | Oxford University Press (OUP), 2022 |
Medientyp: | academicJournal |
DOI: | 10.1093/humrep/deac107.565 |
Schlagwort: |
|
Sonstiges: |
|