LDA measurements of liquid velocities in a refractive index matched packed bubble column
In: Chemical engineering science, Jg. 60 (2005), Heft 3, S. 717-726
academicJournal
- print, 15 ref
Zugriff:
LDA has been used to measure liquid velocities in a small-scale bubble column, internal diameter of 50 mm, packed with glass Raschig rings, 10 and 15 mm. A mixture of benzyl-alcohol and ethyl alcohol was index matched against the packing material. A method to separate the signals from liquid and bubbles was developed. It was found that the axial time-averaged liquid velocity was lower than that obtained in empty bubble columns, and that both the time-averaged liquid velocity and the RMS value of the liquid increased for the larger packing size.