Zum Hauptinhalt springen

Fluid-structure interaction based study on the physiological factors affecting the behaviors of stented and non-stented thoracic aortic aneurysms

XIAOHONG, WANG ; XIAOYANG, LI
In: Journal of biomechanics, Jg. 44 (2011), Heft 12, S. 2177-2184
academicJournal - print, 1 p

Titel:
Fluid-structure interaction based study on the physiological factors affecting the behaviors of stented and non-stented thoracic aortic aneurysms
Autor/in / Beteiligte Person: XIAOHONG, WANG ; XIAOYANG, LI
Link:
Zeitschrift: Journal of biomechanics, Jg. 44 (2011), Heft 12, S. 2177-2184
Veröffentlichung: Kidlington: Elsevier, 2011
Medientyp: academicJournal
Umfang: print, 1 p
ISSN: 0021-9290 (print)
Schlagwort:
  • Biomedical engineering
  • Génie biomédical
  • Orthopedics traumatology
  • Orthopédie, traumatologie
  • Physiology, morphology
  • Physiologie, morphologie
  • Sciences biologiques et medicales
  • Biological and medical sciences
  • Sciences biologiques fondamentales et appliquees. Psychologie
  • Fundamental and applied biological sciences. Psychology
  • Biophysique des tissus, organes et organismes
  • Tissues, organs and organisms biophysics
  • Biomécanique. Biorhéologie
  • Biomechanics. Biorheology
  • Sciences medicales
  • Medical sciences
  • Cardiologie. Appareil circulatoire
  • Cardiology. Vascular system
  • Vaisseaux sanguins et lymphatiques
  • Blood and lymphatic vessels
  • Maladies de l'aorte
  • Diseases of the aorta
  • Chirurgie (generalites). Transplantations, greffes d'organes et de tissus. Pathologie des greffons
  • Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
  • Chirurgie vasculaire: aorte, membres, veine cave. Chirurgie des lymphatiques
  • Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels
  • Pathologie de l'appareil circulatoire
  • Cardiovascular disease
  • Aparato circulatorio patología
  • Anévrysme aortique
  • Aortic aneurysm
  • Aneurisma de aorta
  • Biomécanique
  • Biomechanics
  • Biomecánica
  • Ingeniería biomédica
  • Interaction fluide structure
  • Fluid structure interaction
  • Interacción fluido estructura
  • Stent
  • Stress
  • Estrés
  • Thorax
  • Tórax
  • Traitement instrumental
  • Instrumentation therapy
  • Tratamiento instrumental
  • Prothèse vasculaire
  • Compliance
  • Displacement
  • Drag force
  • Flow behavior
  • Fluid-structure interaction (FSI)
  • Pressure
  • Stent-graft (SG)
  • Thoracic aortic aneurysm (TAA)
Sonstiges:
  • Nachgewiesen in: PASCAL Archive
  • Sprachen: English
  • Original Material: INIST-CNRS
  • Document Type: Article
  • File Description: text
  • Language: English
  • Author Affiliations: Biomechanical Research Laboratory, College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, No. 100 Pingleyuan, Chaoyang District, Beijing, China
  • Rights: Copyright 2015 INIST-CNRS ; CC BY 4.0 ; Sauf mention contraire ci-dessus, le contenu de cette notice bibliographique peut être utilisé dans le cadre d’une licence CC BY 4.0 Inist-CNRS / Unless otherwise stated above, the content of this bibliographic record may be used under a CC BY 4.0 licence by Inist-CNRS / A menos que se haya señalado antes, el contenido de este registro bibliográfico puede ser utilizado al amparo de una licencia CC BY 4.0 Inist-CNRS
  • Notes: Biophysics of tissues, organs and organisms ; Cardiology. Circulatory system ; Surgery (generalities). Transplants, organs and tissues grafting. Graft pathologies

Klicken Sie ein Format an und speichern Sie dann die Daten oder geben Sie eine Empfänger-Adresse ein und lassen Sie sich per Email zusenden.

oder
oder

Wählen Sie das für Sie passende Zitationsformat und kopieren Sie es dann in die Zwischenablage, lassen es sich per Mail zusenden oder speichern es als PDF-Datei.

oder
oder

Bitte prüfen Sie, ob die Zitation formal korrekt ist, bevor Sie sie in einer Arbeit verwenden. Benutzen Sie gegebenenfalls den "Exportieren"-Dialog, wenn Sie ein Literaturverwaltungsprogramm verwenden und die Zitat-Angaben selbst formatieren wollen.

xs 0 - 576
sm 576 - 768
md 768 - 992
lg 992 - 1200
xl 1200 - 1366
xxl 1366 -