Emergency intubation with the combitude® : comparison with the endotracheal airway
In: Annals of emergency medicine, Jg. 22 (1993), Heft 10, S. 1573-1575
academicJournal
- print, 10 ref
Zugriff:
Study objective: To evaluate the safety and effectiveness of thr Combitube® as used by ICU nurses under medical supervision compared with endotracheal airway established by ICU physicians during CPR. Design: Prospective study of ICU patients over a seven-month period. Setting: Medical ICU. Participants: Thirty-seven patients suffering from cardiac arrest. Interventions: Emergency intubation with either the Combitube® by nurses or the endotracheal airway by physicians and subsequent mechanical ventilation. Measurements and main results: Evaluation of blood gases after 20 minutes of mechanical ventilation. Intubation time was shorter for the Combitube® (P<.001).
Titel: |
Emergency intubation with the combitude® : comparison with the endotracheal airway
|
---|---|
Autor/in / Beteiligte Person: | STAUDINGER, T ; BRUGGER, S ; WATSCHINGER, B ; RÖGGLA, M ; DIELACHER, C ; LÖBL, T ; FINK, D ; KLAUSER, R ; FRASS, M |
Link: | |
Zeitschrift: | Annals of emergency medicine, Jg. 22 (1993), Heft 10, S. 1573-1575 |
Veröffentlichung: | New York, NY: Elsevier, 1993 |
Medientyp: | academicJournal |
Umfang: | print, 10 ref |
ISSN: | 0196-0644 (print) |
Schlagwort: |
|
Sonstiges: |
|